3ware Cache flush failed; some data lost

2015.12.03 06:47

관리자 조회 수:94

0025 Cache flush failed; some data lost

Event Type
Error

Cause
The 3ware RAID controller was not able to commit data to the drive(s) during
a caching operation.This is due to a serious drive failure, possibly from a
power outage.

Background Information
The 3ware RAID controller uses caching layer firmware to improve
performance. For write commands this means that the controller
acknowledges it has completed a write operation before the data is committed
to disk. If the 3ware RAID controller cannot commit the data to the drive after
it has acknowledged to the host, this message is posted.

Action
To troubleshoot the reasons for the failure, collect the logs for your system
and contact 3ware technical support at http://www.lsi.com/channel/
ContactUs. For information on collecting logs, search the LSI Knowledge
Base for keyword 12278 (use the Advanced Search) at

https://selfservice.lsi.com/service/main.jsp.




0025 캐시 플러시 실패; 손실 일부 데이터

이벤트 종류
오류

원인
3웨어 RAID 컨트롤러는 동안 드라이브에 데이터를 커밋 할 수 없습니다
캐싱 작업. 이것은에서 가능, 심각한 드라이브 오류로 인해
정전.

배경 정보
3웨어 RAID 컨트롤러는 개선하기 위해 캐싱 층 펌웨어를 사용
공연. 기록 명령이 제어기는 것을 의미
데이터가 커미트되기 전에 그 기록 동작을 완료 한 인정
디스크.3웨어의 RAID 제어기는 드라이브 이후에 데이터를 저지 할 수없는 경우
이 호스트로 인정했다,이 메시지가 게시됩니다.

동작
시스템에 대한 로그를 수집, 실패의 원인을 해결하려면
및 http://www.lsi.com/channel/에서 3웨어 기술 지원 센터에 문의
CONTACTUS. 로그 수집에 대한 자세한 내용은 LSI 기술을 검색
키워드 12278 (고급 검색을 사용)에 대한 자료

https://selfservice.lsi.com/service/main.jsp.